Immersion cooling: the battery of the future

The battery cells are submerged completely in a non-conductive, non-flammable fluid, for markedly higher safety and longer lifetime.

Batteripakke med celler neddyppet i kølevæske

The technology

Cooling at the cell, not from the outside

Immersion cooling is an advanced cooling technology where the battery cells in a BESS installation are submerged completely in a non-conductive, non-flammable dielectric fluid. Instead of cooling from the outside, the cells are cooled directly, which gives markedly better heat dissipation and even temperature control.

By isolating the cells from air and carrying the heat away efficiently, the risk of thermal runaway is reduced considerably. At the same time the cells age more evenly, and the need for active cooling and maintenance falls.

  • Cold supply
  • Warm return
  • Dielectric fluid

The battery pack in 3D. The cells sit in five packs, all fully submerged. Drag to rotate the model, scroll to zoom.

Benefits

Six reasons to choose immersion

Full immersion cooling solves safety, lifetime and economy in one move.

Contact us
  1. 01

    Fire risk removed

    The cells operate fully submerged in insulating coolant, which prevents thermal runaway.

  2. 02

    Even cell temperature

    ΔT ≤ 2 °C between the cells removes imbalance across the system.

  3. 03

    Higher energy density

    More capacity in less space lowers the capital cost.

  4. 04

    Less power for cooling

    Highly efficient cooling cuts the auxiliary power consumption.

  5. 05

    Longer lifetime

    +30 % against air-cooled and +13.6 % against cold plate cooled batteries.

  6. 06

    Triple thermal defence

    Dielectric fluid, inert gas and water deluge keep the temperature below 80 °C.

How it works

The fluid surrounds every single cell

Cold dielectric fluid enters at the bottom of the cabinet, rises through the gaps and surrounds every cell in all five battery packs. The fluid absorbs the heat on its way and leaves the cabinet at the top as warm return.

The technology is particularly well suited to:

  • Stand-alone BESS installations and grid and balancing services
  • Projects in areas with high temperatures
  • Installations with strict safety and reliability requirements
  • Energy efficient cooling of data centres with low PUE
Cross-section of an immersion-cooled battery cabinetCold dielectric fluid enters at the bottom of the cabinet, rises through the gaps and surrounds every single cell in all five battery packs. The fluid absorbs the heat on its way and leaves the cabinet at the top as warm return.
  • Cold supply
  • Warm return
  • Dielectric fluid

Cross-section of the cabinet. The cells sit in five battery packs, all fully submerged.

Kortrong's immersion technology in numbers

immersion-cooled installations worldwide
3 GWh+
scalable from 125 kW
50 MW+
lifetime against air-cooled batteries
+30 %
thermal containment
< 80 °C

Read on

Other solutions and technologies

BESS and AIDC belong together, and the cooling technology decides safety, lifetime and economy alike.

Want to see what immersion cooling can do at your site?

We go through the project and calculate safety, lifetime and economy together with you.